• Hexacon III

 

HEXACON III™ CONTROLLER

Emergency Valve Shutoff System

  • Description

  • Technical Specs

  • Options

  • Actuators

  • Literature

Hexacon III General Description

The Hexacon III controller allows for the control and operation of up to six Eclipse valve actuators. In the event of an emergency, a signal from a leak detector, panic shutoff switch or any other external contact closure will begin the rapid shut off process. The system closes a typical valve opened one full turn in about one second, substantially limiting the size of a chemical release. The controller’s DC power system provides up to 3 days of continuous battery backup to keep your feed system protected even in the event of an AC power interruption.

Features:

  • Electronically Closes Valve In Less Than One Second!
  • OLED System Information Display And Keypad
  • Extensive Onboard Fault/Error Diagnostics
  • Output Relays and RS232 Options Allow Remote Monitoring
  • Battery Operated with Backup Power Protection
  • Separate Emergency and Test Close Torque Values as Recommended by the Chlorine Institute
  • Allows Manual Operation of Valve with Standard Wrench While Actuator Installed
  • Over-Torque Protection
  • NEMA 4X Rated Controller
  • 3 Year Warranty

Hexacon III Technical Specs

Controller Model : 6601.03, 6602.03, 6603.03, 6604.03, 6605.03, 6606.03
Channels : Up to 6 Actuators
Enclosure Dimensions : 14.5 x 16.5 x 8.3 inches (356 x 420 x 210 mm)
Enclosure Weight : 18 lbs (8 kgs)
Battery Weight : 7 lbs (3.2 kgs)
Enclosure Rating : NEMA 4X / IP66
Temperature Range : -10 C to 50 C
Display : 2 line 40 charachter backlit OLED
Power Requirement : 120 - 240 VAC
Power Use : 100 watts
Current : 0.9A @ 120 VAC
Relay Contact Rating : 0.2A @ 24 VDC
Charger : Constant voltage trickle charge
Battery Backup : 3 days, 8.5 amp hour
Emergency Stop Button : Normally Open contact (Optional N.C. Contact)
Warranty : 3 Years
Optional Relay Contacts: (3) per relay card, 5A @ 120 VAC ea.
Optional SCADA Output : RS-232 output of 9 system diagnostics
Optional Second Battery : 3 days, 8.5 amp hour (closes 2 valves at a time)
Accessories : Actuator storage rack (1 per actuator)

 

 

 

 

 

 

Hexacon III Options

  • RS232 Serial Port Output to SCADA
  • Fault Error Output Relay
  • DT-DP Relay (Latching available)
  • Annual Preventative Maintenance Program

 

 

 

 

 

 

 

 

 

 

 

 

The Hexacon III is compatible with the following Actuators:

 

Eclipse Actuator Eclipse XP Actuator
Eclipse Actuator Eclipse XP Actuator

Hexacon III Brochures

 

 

 

Hexacon III Controller

The Hexacon III controller allows operators to remotely close up to six chlorine or sulfur dioxide valves in an emergency situation.



Bulletin 902

Second Battery Option
for Hexacon III Controller

The Second Battery Option for the Hexacon III™ controller decreases the total time required for shutoff, increases battery backup time and adds redundancy for safety.

Bulletin 902.A

 

  • Force Flow